CamCraft

Multi-axis

Machines, kinematics and TCP

What a machine file tells CamCraft

The machine file's parts tree states every axis in the order it moves. A rotary part carries an axis direction (the line it turns about), a travel in degrees, and the parts below it. Three things follow from it:

  • Does the machine tilt the tool? CamCraft answers this geometrically. A machine can tilt if some rotary states a direction that is not the Z column. A C table (axis along Z) tilts nothing. A rotary with no stated direction counts as tilting nothing: capability is claimed, never assumed.
  • Does the rotary turn the work or the tool? A rotary with the head below it in the tree turns the tool; one without turns the work. The index-swing check applies only to work-turning rotaries.
  • Which limits apply? Each rotary's travel is judged per move, and the linear axes are judged against their own strokes.

Table, head and tilt-head machines

  • Table-table or table-only (a trunnion or a 4th-axis table). The rotary turns the work. In the shipped set this is doosan-dnm.mch and tormach-770mx-microarc4.mch, each with one A table about X. The part sits on the rotary, so the work offset must lie on the rotary's centreline (see Indexed work).
  • Head-head or tilt-head. The rotaries carry the spindle, so the part stays still. tilthead.mch is this: A about X, then B about Y, then the head, each limited to -120..120 degrees.
  • Mill-turn. millturn.mch has a C axis about Z. It is a spindle rotary for live-tool and rotary work, not a tilt.

Why it matters:

  • Reach. The pose has to be inside every rotary's travel, and the linear moves inside their strokes. A tilt-head with +-120 degrees cannot stand the tool at a pose 150 degrees from vertical.
  • Which limits apply. A machine whose only rotary is about X is judged through the tool axis: a stated pose such as A0 B180 reads as its A180. Every other machine is judged letter by letter: an A trunnion asked for a B turn is refused by name, since CamCraft never solves for another axis combination.
  • Singularities. CamCraft does not solve inverse kinematics: the generators state the tool axis and the post (or the control) turns it into angles. A pose where two rotaries line up (tool straight along an axis) is where a real control swings an axis fast. CamCraft has no singularity check of its own; prove the program out in the control's own simulation.

TCP, RTCP and no TCP

TCP (also called RTCP or TCPM) is the control's mode where the programmed point is the tool tip, and the control moves the linear axes to keep the tip on the path while the rotaries turn. Without it, the program has to contain the compensating linear moves, and CamCraft's posts do not compute those.

The post reads machine.rtcp from the machine file (true when a rotary states a direction off Z) and does the following:

PostTilted moves
fanuc.cpsWith machine.rtcp true, arms G43.4 H<tool> once per tool and writes the rotary words, modally. Refuses (counted warning, post blocked) a tilt on a machine with no tilting rotary, a letter the machine states no rotary for, a tilt inside a canned-cycle group, and a lone rotary stated along -X.
doosan-dnm.cpsThe same G43.4 path when machine.rtcp is true. When it is false, a no-TCP path indexes an A table only: it needs rotary clamp and unclamp codes declared by the machine or post options, and refuses B or C words.
tormach.cpsNo TCP. A table about X is indexed between operations and A never changes inside one. See Indexed work.
haas.cps, heidenhain.cps, mazak.cps, sinumerik.cpsRefuse every tilted move: these posts have no RTCP output.
carvera.cpsRefuses every tilted move: the post is 3-axis.
fanuc-lathe.cps, tormach-lathe.cpsLathe posts; fanuc-lathe.cps handles C-axis live-tool sections, and refuses A/B words.

A refused tilt is a counted warning that blocks the post, so it cannot slip into a file silently.

When your control has no TCP

If the control has no TCP, use only indexed work (3+1 or 3+2) with a post that indexes. Do not post simultaneous work to it. Known gap (#950): on the no-TCP path of doosan-dnm.cps, the post assumes A0 at the start of the program and after a tool change, so an A0 section writes no A word even though the table may stand elsewhere. Until that is fixed, start every program and every tool with an operation that moves A explicitly, or check the posted file for the missing A word.